View RSS Feed

Heineken's Garage

Climate Control Unit (CCU)

Rate this Entry
Introduction
The Climate Control Unit (CCU) of the NSX controls heating, cooling and ventilation of the passenger cabin. It utilizes several electrical sensors and actuators across the vehicle to do so:

Sensors Actuators
  • Outside temperature
  • Cabin temperature
  • Sunlight
  • Heater core temperature
  • Evaporator temperature
  • Blower Motor
  • Mode control motor
  • Vent door control motor
  • Air mix control motor
  • Recirculation control motor


Self Check
Except for the blower motor, above items can be checked by means of a CCU self check feature. It's activated by pressing both the left (Auto) and right (Off) button on the CCU at the same time. Each character on the display (except "FULL", AUTO" and the temperature value) represents a detected fault.

Click image for larger version. 

Name:	$_10.jpg 
Views:	899 
Size:	55.0 KB 
ID:	14043
No errors dected

To ensure proper detection (especially for motor related issues) the CCU should be run in full automatic mode, then turn the temperature control from lowest to highest in slow steps. This makes the CCU run all actuators and confirm potential issues.

Indicator Fault
MODE Cabin temperature sensor - open/short circuit
Name:  457522-200.png
Views: 432
Size:  543 Bytes Outside temperature sensor - open/short circuit
Name:  25426s.png
Views: 467
Size:  855 Bytes Sunlight sensor - open/short circuit
Name:  112-1123569fs.png
Views: 456
Size:  754 Bytes Heater core temperature sensor - open/short circuit
Name:  sitting-icon-16fs.png
Views: 457
Size:  422 Bytes Evaporator temperature sensor - open/short circuit
A/C Air mix control motor - open/short circuit or door stuck
ON Mode control motor - mode door stuck or position signal circuit
OFF Recirculation control motor - position signal circuit
Name:  457522-200.png
Views: 432
Size:  543 Bytes-Button LED Vent door control motor - open/short circuit or door stuck
Note that errors are not stored and will disappear upon ignition-off.


Auto Check Routine
An additional automatic check routine is available by setting the Fan-dial to "AUTO" and pressing both the Auto and mode button at the same time before switching on the ignition. Once activated the CCU is cycling through an combination of all settings which can be used to confirm that all of them are working as expected.

Temperature Fan Air Mix Door Mode Recirculate A/C
88 off full open Name:  457522-200.png
Views: 432
Size:  543 Bytes no off
1 low half closed Name:  457522-200.png
Views: 432
Size:  543 Bytes no on
2 .. half closed Name:  112-1123569fs.png
Views: 456
Size:  754 BytesName:  sitting-icon-16fs.png
Views: 457
Size:  422 Bytes yes on
3 .. full closed Name:  25426s.png
Views: 467
Size:  855 BytesName:  sitting-icon-16fs.png
Views: 457
Size:  422 BytesName:  112-1123569fs.png
Views: 456
Size:  754 BytesName:  sitting-icon-16fs.png
Views: 457
Size:  422 Bytes yes on
4 high full closed Name:  25426s.png
Views: 467
Size:  855 BytesName:  sitting-icon-16fs.png
Views: 457
Size:  422 Bytes yes on
5 high half open Name:  112-1123569fs.png
Views: 456
Size:  754 BytesName:  sitting-icon-16fs.png
Views: 457
Size:  422 Bytes yes on
6 .. half open Name:  112-1123569fs.png
Views: 456
Size:  754 BytesName:  sitting-icon-16fs.png
Views: 457
Size:  422 BytesName:  457522-200.png
Views: 432
Size:  543 Bytes no off
7 .. full open Name:  112-1123569fs.png
Views: 456
Size:  754 BytesName:  sitting-icon-16fs.png
Views: 457
Size:  422 BytesName:  457522-200.png
Views: 432
Size:  543 Bytes no off
8 low full open Name:  457522-200.png
Views: 432
Size:  543 Bytes no off
88 off full open Name:  457522-200.png
Views: 432
Size:  543 Bytes no off

This video shows the auto check routine in action: https://www.youtube.com/watch?v=c28_T5Ix_JY


Known Issues
Similar to many other ECUs in the NSX the CCU is subject to capacitor leakage and resulting damage. A typical symptom is a fan working on the highest setting only.
If these or other unusual effects are observed and/or the self check shows detected faults which can't be confirmed, action should be taken before the unit becomes irreparably damaged. Preventive replacement of the capacitors is highly recommended.

Updated 10-06-2021 at 08:16 PM by Heineken

Tags: None Add / Edit Tags
Categories
Technical Information

Comments