As I want to test the two boards (A & B) on the same day, decided to finish this board within today so that I don't need to remove my centre console again. ...
As always, replacing capacitors is less than 10% of the actual service. Most of the time is being spent for testing and checking the circuit. Hard wire used to create the missing tracks and pads to strengthen the connection and GND plains. ...
Another owner hand carried his board to my place. He told me that at the moment, he was not experiencing any A/C related issues but wanted to have preventative maintenance. He also told me that he checked the capacitors and he didn’t see any issues with them. Well, when I looked at the board, I was quite surprised that the owner was not experiencing any issues and didn’t spot none of the following severe ...
Started to work on the CCU boards. The owner hand carried his board to my place as we know each other for many years. He brought two boards at the same time. One for his NSX and the other one was just sitting in his storage and he wanted to see whether it could be of any use or not. As he removed all of the fixings from the board, I was able to show the condition of it while he was waiting. As I knew the ...
Finally, all of the electrical components were back in place on my NSX so managed to re-connect the battery. Although I can’t start the engine yet, decided to check the two CCU boards. One of the board on my NSX. The Lot # will tell which one. ...
Updated 06-02-2012 at 10:03 AM by Kaz-kzukNA1 (Corrected the sensor input info.)